Sinewave
   
   

Pure Sine Wave Long Back-up UPS consists of a sophisticated design producing the AC wave power output similar to that you would get from your house power point. These UPS’s will support all the expensive and sensitive household equipments which will fail to run from the power output of a modified wave UPS.

The high quality power output from the pure sine wave UPS will maintain the unit’s power supply throughout, thus supporting these appliances like your household power unit will. This being the case it is always better to invest in a pure sine wave UPS and get a quality power supply that will support all your equipments without any trouble.

Luminous Sine wave UPS’s are packed with a range of user-friendly features, these are symbols of convenience and comfort. Very little maintenance, no noise… these Sine Wave UPS stand for powerful performance with all-round performance.


Features & Protection

  • Micro controller based design
  • Regulated output voltage window during regulated UPS mode
  • Can run single PC up to 8hrs. With 12 V 150 AH battery
  • Selectable battery option
  • Pre-loaded battery management software
  • Charges battery double fast
  • Regulated battery charging from 120 V to 300 V
  • Automatic holiday mode preserves battery charge
  • Advanced digital display
  • Audio alarms on mains fail, Charger fuse blown, battery low and no load shutdown
  • Phase reversal protection
  • Overload with auto re-set
  • Battery Deep Discharge protection with two times reset options
  • Ultra Fast Short Circuit Protection
  • Battery reverse polarity protection
  • Miniature circuit breaker for overload and short circuit protection in mains mode instead of cartridge fuse
  • DC over Voltage protection.

Sinewave - 600Va, 800Va, 1400Va 
Input Regulated UPS mode
Under Voltage  180 +/- 5 V
Undervoltage Restoration  185 +/- 5 V
Over Voltage  260 +/- 5 V
Over Voltage Restoration  255 +/- 5 V
Unregulated UPS mode
Under Voltage  100 +/- 10 V
Undervoltage Restoration  115 +/- 10 V
Over Voltage  285 +/- 10 V
Over Voltage Restoration  270 +/- 10V
Output Voltage (UPS Mode)  230 V(Nominal)
Voltage (Mains Mode)  Same as Input
Frequency (UPS Mode)  50Hz.±2%
Frequency (Mains Mode)  Same as Input (45-55 Hz.)
Overload  > 110 %
Transfer Time (typical a.s)  10ms.
Battery Type  12V/120AH-150AH Lead Acid Type
Number  1
Typical Recharge Time  10-12 Hrs.
Protection  Battery Deep Discharge, Reverse Polarity, DC Overvoltage
LED Display UPS ON  Red
SWITCH ON  White
Low Battery Pre-Alarm  UPS ON+LOW BATTERY LED BLINKS
Battery Low  Red
Mains On  Red
Smart Charge  Red (Along with Mains On LED)
Overload  Red
Short Circuit  OVERLOAD RED LED BLINKING
No Load Shut Down  Red
Battery Charged  Mains On LED steady
MCB Trip  Mains On+Smart charge blinking
Alarms Low Battery Pre-Alarm  Beeps every 1.5 Minutes
Low Battery Trip  Beeps Continuously for 10 seconds
Overload  Beeps Continuously for 10 seconds
Mains to UPS  Beeps every 2 seconds for 5 times
Short Circuit  Beeps Continuously for 10 seconds
No Load Shut Down  Beeps Continuously for 10 seconds
MCB Trip  Beeps every 12 minutes
Environmental Operating Temperature  0-45o C  (32-113 o  F)
Storage Temperature  0-45o C  (32-113 o  F)
Humidity  0-95 % RH non -condensing