Downloads :      Leaflet   |   Manual
Squarewave
   
   
Luminous presents the latest breakthrough in the world of power back up UPS. A powerhouse of performance packed in a highly attractive design these long back up UPS boast of phenomenally advanced features that give in a unique ability to run a PC for hours together, even in the bleakest of power situations. We at Luminous value the convenience and comfort of the consumer above anything else. Very little maintenance, powerful performance and all-round protection makes this series a value for money investment.
Features & Protection

  • Micro controller based design
  • Free Pre-loaded battery management software.
  • SMD Technology for reliable and compact design
  • Battery charging commences even at as low as 120 Volt Mains voltage
  • Auto holiday mode preserves battery charge while you are away from home
  • Intelligent thermal management
  • Visual Indicators: Mains On, UPS On, Switch Status, Smart Charge, Overload/ Short Circuit Trip, Charger Fuse Blown, Battery Low
  • Trip and No Load Shutdown
  • Audio Alarms: Mains Fail, Fuse Fail, Battery Low Pre-alarm, Overload Trip, Battery Low Trip and No Load Shutdown
  • Ensures faster battery charging
  • Advanced battery management, which enhances battery life up to 70%
  • Negligible battery-water loss
  • Intelligent continuous charging profile adjustment
  • Overload with Auto Reset
  • Battery Deep Discharge Protection with Reset Option
  • Ultra-Fast Short Circuit Protection
  • Battery Reverse Polarity Protec

Squarewave - 600Va, 800Va, 1400Va 
Input Regulated UPS mode
Under Voltage  180 +/- 5 V
Undervoltage Restoration  185 +/- 5 V
Over Voltage  265 +/- 5 V
Over Voltage Restoration  260 +/- 5 V
Unregulated UPS mode
Under Voltage  100 +/- 10 V
Undervoltage Restoration  110 +/- 10 V
Over Voltage  300 +/- 10 V
Over Voltage Restoration  290 +/- 10V
Output Voltage (UPS Mode)  230 V(Nominal)
Voltage (Mains Mode)  Same as Input
Frequency (UPS Mode)  50Hz.±2%
Frequency (Mains Mode)  Same as Input (45-55 Hz.)
Overload  > 110 %
Transfer Time (typical a.s)  10ms.
Battery Type  12V/120AH-150AH Lead Acid Type
Number  1
Typical Recharge Time  10-12 Hrs.
Protection  Battery Deep Discharge, Reverse Polarity, DC Overvoltage
LED Display UPS ON  Red
SWITCH ON  White
Low Battery Pre-Alarm  UPS ON+LOW BATTERY LED BLINKS
Battery Low  Red
Mains On  Red
Smart Charge  Red (Along with Mains On LED)
Overload  Red
Short Circuit  OVERLOAD BLINKING
No Load Shut Down  Red
Battery Charged  Mains On LED steady
Charging Fuse Blown  Mains On (Continuos) with Smart Charge LED (blinking)
Alarms Low Battery Pre-Alarm  Beeps every 10 seconds
Low Battery Trip  Beeps Continuously for 10 seconds
Overload  Beeps Continuously for 10 seconds
Mains to UPS  Beeps every 2 seconds for 5 times
Short Circuit  Beeps Continuously for 10 seconds
No Load Shut Down  Beeps Continuously for 10 seconds
Charging Fuse Blown  Beeps Continuously for 10 seconds
Environmental Operating Temperature  0-45o C  (32-113 o  F)
Storage Temperature  0-45o C  (32-113 o  F)
Humidity  0-95 % RH non -condensing